Created on 07/08/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
RSJC
Pilot operated, balanced piston sequence valve
SERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the
inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port
1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence),
up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in
the return line.
TECHNICAL DATA
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,25 - 0,33 L/min.
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 80 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-019-007
Seal kit - Cartridge Polyurethane: 990-019-002
Seal kit - Cartridge Viton: 990-019-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
Y Tri-Grip Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi (70
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70
bar) Standard Setting
C 150 - 6000 psi (10,5 - 420 bar), 1000 psi
(70 bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/RSJC
TECHNICAL FEATURES
All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
Model Code Example: RSJCLANCONFIGURATION OPTIONS
Created on 07/08/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
The main stage orifice is protected by a 150 micron stainless steel screen.
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
Not suitable for use in load holding applications due to spool leakage.
W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full
range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
RSJC8 Pilot operated, balanced piston sequence main stage with integral T-8A control cavity